<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-10 18-17-14
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 71 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 62 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19059 1,6633
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,8 dBr 4,38 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 18:17, 10.08.2024
RT
"Lyömättömät! "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 1,6633 Acquired: 2024/08/10 18.16.10 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,1 dBr MIN: 1,8 dBr AVE: 4,38 dBr % above 12,2 dBr: 0,0 Last value: 5,1 dBr (2024/08/10 18.16.10) 18.02 18.04 18.06 18.08 18.10 18.12 18.14 18.16 0 2 4 6 Pm [dBr]